A recent install of a Dru 44 with a twin wall Stainless Steel Flue to replace a Stanley that had been installed with a single skin flue.
Single skin flue all the way up (and outside) is not only against every rule in the book, but will also cause the stove to perform inefficiently due to poor flue draw.
This is caused when the flue gases travel up the flue and are cooled down too quickly, stopping the thermal up drafts of the flue gases and producing high levels of condensation which is highly corrosive to the stove and the flue pipe itself, that's not to mention the danger in the heat transfer from the single skin pipe beside the insulation in the cavity wall.
Installs such as this can be completed in one working day, giving you the piece of mind that your stove will work properly and more importantly safely.
For more information please contact us on 074 9124144 or on info@sprattfireplaces.ie (click link)